Worked example / 12×12 ft bedroom

12×12 ft bedroom with 12×12 in tile: 12 boxes, $704.00

For a 12×12 ft bedroom (12 × 12 ft, 8 ft walls) covered in 12×12 in tile using the “Standard grid (10% allowance)” layout pattern, RoomTakeoff's quantity method computes 12 tile boxes for a grid of 12 columns by 12 rows (144 cells), 3 gallons of wall paint, 50 linear ft of trim, and an entered-price material total of $704.00, as of 2026-09-11 (RoomTakeoff, method 1.0.0).

Floor area
144 sq ft
Tile boxes
12
Wall paint
3 gal
Trim
50 linear ft
Grout
1 bag
Material total
$704.00
Purchase and installation schedule
StageMaterialQuantityEstimated costDependency
1 · VerifySubstrate / waterproofingNot calculatedNot includedConfirm substrate, flatness, moisture, and installation system
2 · OrderTile12 boxes$432.00Confirm lot, orientation, transitions, and actual box contents
3 · OrderGrout1 bag$12.00Generic coverage formula; confirm with your grout product
4 · FinishWall paint3 gallons$135.00Surface preparation and manufacturer coverage
5 · FitTrim50 linear ft$125.00Finished floor elevation and opening measurements

How the 12 boxes are worked out

The grid needs 144 whole tiles (12 × 12, each partial edge cell counted as a full tile). Adding the 10 percent allowance gives 159 tiles, and at 14 tiles per box that rounds up to 12 boxes, or 168 tiles with 24 beyond the bare grid. Walls: 384 sq ft gross minus 30 sq ft of openings leaves 354 sq ft, which at 2 coats needs 3 gallons. Trim: 48 ft of perimeter minus a 3 ft door, plus the allowance, is 50 ft.

Waste by layout in this room

12×12 ft bedroom, 12×12 in tile: boxes by layout pattern
Layout patternTiles orderedBoxes
Standard grid (10% allowance)15912
Straight lay, clean cuts (5% allowance)15211
Brick or diagonal offset (15% allowance)16612
Herringbone or complex (20% allowance)17313

A diagonal or offset lay (15 percent planning allowance) needs 12 boxes here against 11 boxes for a straight lay with clean cuts (5 percent), a difference of 1 box. The drawing and grid count always assume a straight grid; only the allowance changes.

Assumptions behind this number

This worked example uses a 8 ft ceiling, 30 sq ft of wall openings, a 3 ft door/opening deduction from trim, a 0.125 in grout joint, 14 tiles per box, 2 paint coats at 350 sq ft per gallon coverage, and the Standard grid (10% allowance) tile/trim allowance. Every tile cell, including a partial edge cell, consumes one whole tile: there is no offcut reuse, movement-gap, or irregular-room modeling. Change any of these assumptions in the live planner below to match your actual room, tile, and prices; this page is a starting estimate, not a purchase order. Waste percentages (5, 10, 15 and 20 percent), 350 sq ft per gallon paint coverage, 2 coats and a 1/8 in grout joint are RoomTakeoff planning assumptions, not figures taken from a manufacturer or standards document. Check the label on your tile, paint and trim, and confirm installation practice with the tile manufacturer or the Tile Council of North America resources linked below.

Reference sources

Tile Council of North America installation resources EPA renovation lead-safety information

Other tile sizes in this room

Related rooms

Open this exact plan in RoomTakeoff